INDUSTRIAL OVENS FOR THE PROCESS OF FIRING BIOMEDICAL COMPONENTS

The oven was designed to perform with an extremely accurate cycle.

The requirement of the process involved work cycles at temperatures of +200°c, with accuracy +/-1°c with respect to the set point.

The accuracy of the distribution of the temperature was based on the need to avoid influencing the good quality of the product, criticality of extreme importance owing to the market sector in which the customer operates.

The double door offers the customer loading of the oven in fifo mode.

The two doors, one manual and the other automatic guillotine type provide the customer utmost versatility of use as regards the different types of material to be subjected to the heating cycle.

The design of the safety devices and guillotine door control circuits was studied thoroughly to ensure utmost safety of use for the operators.

Technical data

Thermoregulation areas: 1
Working dimensions WxDxH in mm: 1000 x 1000 x 1250
Installation site : Indoor
Heating power supply: Electric
Nominal operating temperature: Up to +200°C
Temperature accuracy: +/- 1°C
Doors: 2 doors (1 "Guillotine" type operated automatically - 1 manually operated single leaf door) for fifo loading mode
Base: The oven was constructed with insulated bottom with structure on feet
Finish: The entire oven is made of aisi304 stainless steel, exterior painted RAL 7035 with standard cycle.
Control panel (Process + Logic): Built in control panel and wiring ducts. Heating process control in PID mode
Optional: 3.5" touch screen programmer panel for control of the temperature cycles and data recording.
Construction entirely in AISI304 stainless steel.
Double front/rear door with fifo loading mode.
1 automatic pedal-operated guillotine type door.
Ceiling-mounted parts-holder rails to hold the workpieces.
Interlocked extraction cycle with heating cycle and performed by the customer's central system.